如何修復(fù)內(nèi)窺鏡顯示器的常見故障

來源:http://foxnewsss.com/ 發(fā)布時(shí)間:2022-07-07 瀏覽量:0

內(nèi)窺鏡經(jīng)過長期的手術(shù)室儀器設(shè)備維修,發(fā)現(xiàn)內(nèi)窺鏡故障根據(jù)維修難易和故障大小,可分為復(fù)雜故障、中等故障和簡單故障。無論何種故障都必須懂得內(nèi)窺鏡的工作原理,憑借豐富的維修經(jīng)驗(yàn)技術(shù)處理。
After long-term maintenance of instruments and equipment in the operating room, it is found that endoscope faults can be divided into complex faults, medium faults and simple faults according to the difficulty and size of maintenance. No matter what kind of fault, we must understand the working principle of the endoscope and deal with it with rich maintenance experience and technology.
一、圖像偏色
1、 Image color deviation
在白平衡后和排除其他配套設(shè)備的影響下都無法還原景物的顏色時(shí),我們認(rèn)為可能是由導(dǎo)線老化信號(hào)傳遞缺陷引起的,也可能是攝像頭電路元件老化變質(zhì),又或者是由攝像頭CCD老化引起。此時(shí)我們只需更換內(nèi)窺鏡顯示器相應(yīng)的配件則可。
When the color of the scene cannot be restored after the white balance and excluding the influence of other supporting equipment, we think it may be caused by the aging of the wire, the defect of signal transmission, the aging and deterioration of the camera circuit elements, or the aging of the camera CCD. At this time, we only need to replace the corresponding accessories of the endoscope display.
內(nèi)窺鏡設(shè)備維修
二、圖像有干擾
2、 Image interference
一般是因?yàn)橛秒姷兜雀哳l設(shè)備的時(shí)候?qū)€路產(chǎn)生干擾,這時(shí)候我們要檢查的是攝像頭與連接中的屏蔽線是否有接通。還有一種情況就是沒有使用高頻設(shè)備的時(shí)候也會(huì)出現(xiàn)干擾條紋,這時(shí)候是連接線信號(hào)線由于長期使用,屏蔽層磨損。
Generally, it is because the use of high-frequency equipment such as electric knife interferes with the line. At this time, we need to check whether the camera is connected to the shielding wire in connection. There is also a case that interference stripes will appear when high-frequency equipment is not used. At this time, the shielding layer of the connecting line signal line is worn due to long-term use.
需要看是攝像頭的連接處出問題還是整條線體老化,前者需要重新焊接,而后者則需要更換連接導(dǎo)線了。目前更換原裝進(jìn)口的3m長的連接導(dǎo)線價(jià)格在10000RMB左右。所以內(nèi)窺鏡顯示器使用過程中盡量避免導(dǎo)線在地上被儀器車或手術(shù)車碾過。
We need to see whether the connection of the camera is faulty or the whole line is aging. The former needs to be re welded, while the latter needs to replace the connecting wire. At present, the price of replacing the original imported 3M long connecting wire is about 10000RMB. Therefore, during the use of the endoscope display, try to avoid the wire being run over by the instrument car or surgical car on the ground.
內(nèi)窺鏡設(shè)備維修廠家提醒您,內(nèi)窺鏡在使用后的保養(yǎng)程度,會(huì)直接影響硬鏡的壽命。只有認(rèn)真地做好日常保養(yǎng),才能夠延長硬鏡的使用壽命、減少硬鏡的磨損和老化、降低維修成本、減少不必要的停機(jī)時(shí)間。
The endoscope equipment maintenance manufacturer reminds you that the maintenance degree of the endoscope after use will directly affect the service life of the hard mirror. Only by doing a good job in daily maintenance can we prolong the service life of hard mirrors, reduce the wear and aging of hard mirrors, reduce maintenance costs and reduce unnecessary downtime.
以上就是問題解答的相關(guān)內(nèi)容了,希望能夠幫助到大家,如對(duì)這一問題還存在任何疑問,都?xì)g迎關(guān)注我們網(wǎng)站http://foxnewsss.com并咨詢我們的工作人員,將竭誠為您服務(wù)。
The above is the relevant content of the question answer. I hope it can help you. If you still have any questions about this problem, you are welcome to follow our website http://foxnewsss.com And consult our staff, will serve you wholeheartedly.
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國際信息產(chǎn)業(yè)園6號(hào)樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國際信息產(chǎn)業(yè)園6號(hào)樓101-2室  湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號(hào)