使用醫(yī)用內(nèi)窺鏡攝像機(jī)注意事項(xiàng)

來(lái)源:http://foxnewsss.com/ 發(fā)布時(shí)間:2022-10-25 瀏覽量:0

醫(yī)用內(nèi)窺鏡攝像機(jī)與監(jiān)視器及光學(xué)內(nèi)窺鏡連接,可以幫助醫(yī)生在手術(shù)中,清楚地查看病變位置,在可視的情況下手術(shù),大大地提高了手術(shù)成功率。下面內(nèi)窺鏡設(shè)備維修人員來(lái)講講使用醫(yī)用內(nèi)窺鏡攝像機(jī)注意事項(xiàng)。
The connection of the medical endoscope camera with the monitor and the optical endoscope can help doctors to clearly view the location of the lesions during surgery, and operate under visual conditions, greatly improving the success rate of surgery. The following endoscope equipment maintenance personnel will talk about the precautions for using the medical endoscope camera.
使用醫(yī)用內(nèi)窺鏡攝像機(jī)注意事項(xiàng):
Precautions for using medical endoscope camera:
1)使用過(guò)程中導(dǎo)光束不要打折,以免對(duì)導(dǎo)光束有損壞,影響光的傳輸;
1) Do not discount the guide beam during use to avoid damage to the guide beam and influence the light transmission;
2)兩次開(kāi)關(guān)機(jī)之間需要間隔2-3秒;
2) The interval between two switching on and off is 2-3 seconds;
3)在通電情況下,不得搬動(dòng)或搖動(dòng)儀器,不得接插、拆裝儀器的任何部件;
3) Under the condition of power on, the instrument shall not be moved or shaken, and any part of the instrument shall not be plugged or disassembled;
4)儀器應(yīng)放置在清潔通風(fēng)的室內(nèi)使用,避免與化學(xué)物品及電磁、電場(chǎng)力強(qiáng)的電器放在一起;
4) The instrument shall be placed in a clean and ventilated room for use and shall not be placed with chemicals and electrical appliances with strong electromagnetic and electric field forces;
5)儀器表面由于靜電作用,易吸收灰塵,擦拭時(shí)請(qǐng)先斷開(kāi)電源,用較為柔軟的脫脂棉擦拭,避免表面劃傷;
5) The surface of the instrument is easy to absorb dust due to static electricity. Please disconnect the power supply before wiping, and use a soft absorbent cotton to avoid scratches on the surface;
6)攝像機(jī)鏡頭表面有灰塵時(shí),應(yīng)用用脫脂棉和酒精擦拭;
6) When there is dust on the camera lens surface, it should be wiped with absorbent cotton and alcohol;
7)儀器應(yīng)避免頻繁的開(kāi)關(guān),否則易損壞。儀器不用時(shí),應(yīng)關(guān)閉電源,拔下外電源,蓋好蓋布;長(zhǎng)期不用時(shí),應(yīng)擦拭干凈,放在包裝箱內(nèi),并定期打開(kāi)通電運(yùn)行一下(一般每隔一個(gè)月通電運(yùn)行一次);
7) The instrument should avoid frequent switching, otherwise it is easy to be damaged. When the instrument is not in use, turn off the power supply, unplug the external power supply, and cover it with cloth; When it is not used for a long time, it should be wiped clean, put in the packaging box, and open it regularly for power on operation (generally once every other month);
內(nèi)窺鏡設(shè)備維修
8)內(nèi)窺鏡設(shè)備失去功能的故障時(shí),禁止自行打開(kāi)機(jī)殼,應(yīng)與公司聯(lián)系維修;
8) When the endoscope equipment fails to function, it is prohibited to open the casing by yourself, and the company should be contacted for maintenance;
9)儀器應(yīng)用部分的表面溫度超過(guò)41℃,暫停使用,使其冷卻后再繼續(xù)使用,以免燙傷;
9) If the surface temperature of the application part of the instrument exceeds 41 ℃, the instrument shall be suspended for further use after being cooled to avoid scalding;
10)更換照明LED光源時(shí),一定要專門的人士負(fù)責(zé)更換,禁止非專門的人士操作;
10) When replacing the LED light source, special personnel must be responsible for the replacement, and non special personnel are not allowed to operate;
11)內(nèi)窺鏡使用前,要配上適宜的濾光片,以防止內(nèi)窺鏡光出射窗傳輸高能射光時(shí),傷害眼睛;
11) Before the use of the endoscope, appropriate filters should be equipped to prevent eye injury when the endoscope light exit window transmits high-energy light;
12)設(shè)備的安裝和調(diào)試只能由經(jīng)過(guò)正規(guī)培訓(xùn)、具有操作資格的醫(yī)技人員完成。
12) The installation and commissioning of the equipment can only be completed by medical technicians with formal training and operation qualification.
13)每次使用前須檢查內(nèi)窺鏡和內(nèi)窺鏡附件部分是否引起安全危害:如表面粗糙、尖銳邊緣或突出物;
13) Before each use, check whether the endoscope and its accessories cause safety hazards: such as rough surface, sharp edges or protrusions;
以上是關(guān)于使用醫(yī)用內(nèi)窺鏡攝像機(jī)注意事項(xiàng)的介紹,希望可以幫助大家更好地了解機(jī)器,正確的操作可以延長(zhǎng)機(jī)器的使用壽命。更多的相關(guān)事項(xiàng)就來(lái)我們網(wǎng)站http://foxnewsss.com咨詢了解吧!
The above is about the precautions for using the medical endoscope camera. I hope it can help you better understand the machine. Correct operation can extend the service life of the machine. More related matters come to our website http://foxnewsss.com Ask and understand!
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室
  • 匠仁醫(yī)療湖南長(zhǎng)沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室  湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號(hào)